Form 216
SOR® Pressure Switches
are rugged fi eld-mounted instruments. The
pressure sensing element of the SOR pressure switch is a force-balance, piston-actuated assembly. The sensing element is sealed by a fl exible diaphragm and a static o-ring. A wide selection of wetted parts materials for media compatibility and containment are available. A metal diaphragm may be welded to the
pressure port for certain applications, thereby eliminating the o-ring.
Application Information
The SOR pressure switches in this catalog are suitable for a variety of process applications. Basic models with standard wetted parts are normally suitable for air, oil, water and non-corrosive processes. See the Quick Selection Guide on pages 4 and 5. Specifi c application requirements can normally be met by selecting optional components, such as switching elements, diaphragm systems and pressure ports. See How to Order on page 3. Certain applications may require customized specials. Consult the SOR representative in your area or the factory.
This catalog describes switches that are: • General Purpose• Weathertight
• Conventional Explosion Proof
Other specifi c types of switches available through your SOR representative are:• Hermetically Sealed (for hazardous locations)
• Pivot Seal (for high shock pressures and cycle rates)• Differential Pressure
• Temperature (remote and direct mount)• Electronic and Mechanical Level• Electronic Pressure
6B3
6NN
12L
www.sorinc.comwww.sorinc.com913-888-2630Form 216Registered Quality System to ISO 9001:2000913-888-26301/32Pressure and Vacuum Switches
Features
Complete Product Line
Standard models and customized specials cover pressure range from 30 inches Hg VAC to 4000 psi.
Cost Effective
Simple and fast installation without
special tools, long service life, no
required periodic service or spare parts.
Robust Construction
ed, ATEX Rugged, high-cycle rate tolerance, long UL Listed, CSA Certifi
ed, FM, JIS/RIIS Approved life, not critical to vibration, high overrange CertifiModelsand proof pressures, excellent corrosion
Meets most code and customer resistance to hostile environments.
requirements.
Instrument Quality
Built-In QualityHigh resolution of Set Points, high
Rigid quality standards maintained from repeatability, narrow dead band,
raw material to fi nished product. negligible temperature effect.
Wetted Parts
Wide selection materials, process connection confi gurations and sizes. Optional “fi re-safe” pressure sensor.
Service
Factory sales engineers and area SOR representatives provide effective and prompt worldwide service.
Snap-Action Electrical Switching
DeliveryWide selection UL Listed and CSA
Routine shipments 7 to 10 working Certifi ed switching elements for AC
days. Emergency shipments via same and DC service. Optional “hermetically
day air.sealed” capsule for hazardous and hostile
environments.
WarrantyField Adjustable3 years from date of manufacture.
Self-locking adjustment, no special tools required. No-charge factory calibration.
Form 2162/32Registered Quality System to ISO 9001:2000www.sorinc.com 913-888-2630Pressure and Vacuum Switches
Model Number System
How to Order
6NN-K5-M4-C2A-YY
Piston
Housing
Switching Range ElementSpring
Diaphragm
Pressure Port
Accessories
Quick Selection Guide
Basic SOR pressure switches with standard wetted parts are normally suitable for air, oil, water and non-corrosive processes. The Quick Selection Guide on pages 4 and 5 shows these basic SOR pressure and vacuum switches. Corrosive service and particular customer requirements may require optional components. Refer to How to Order section below to build a customized model number or the dedicated page to locate optional components, such as switching elements, diaphragm systems, pressure ports and accessories. Each position in the model number, except Accessories, must have a designator.
Design and specifi cations are subject to change without notice. For latest revision, see www.sorinc.com.
Applications
SOR pressure switches in this catalog are suitable for a wide variety of continuous pressure applications. Specifi c application requirements can normally be met by selecting optional components, such as, switching elements, diaphragm systems and pressure ports. Certain applications may require customized specials. Consult the SOR representative in your area or the factory.
How to Order
Information and data in this catalog are formatted to provide a convenient guide to assist
instrument engineers, plant engineers and end users in selecting pressure switches for their unique applications.
Steps 1 through 5 are required. Step 6 is optional. Orders must have complete Model Numbers, i.e. each component must have a designator.
Step 1: Select Piston-Spring adjustable range/Set Point from Specifi cations (pages 7 & 8). (Piston/Spring combination determines adjustable range.)Step 2: Select Housing for type of pressure switch and service (page 9).
Step 3: Select electrical Switching Element for electrical service (pages 10 & 11).Step 4: Select Diaphragm and O-Ring for process compatibility and containment (pages 12 & 13).Step 5:Select Pressure Port for process compatibility and connection (page 14).Step 6: Select Accessories required for service (page 16).
www.sorinc.com913-888-2630Registered Quality System to ISO 9001:2000Form 2163/32Pressure and Vacuum
Quick Selection Guide - PressureSwitches
Basic SOR pressure switches with standard wetted parts are normally suitable for air, oil, water
and non-corrosive processes. Corrosive service and particular customer requirements may require optional components. Refer to How to Order on page 3 to locate optional components, such as, housing, switching elements, diaphragm systems, pressure ports and accessories. Each position in the model number, except Accessories, must have a designator.
Weathertight Model Number12NN - N66 - N4 - B1A12NN - K614 - N4 - B1A12NN - K2 - N4 - B1AWeathertight
Typical Dead Band(increasing pressure) psi psi (in. wc.)(in. wc.)(0.6 to 2.5)(2.5 to 45.0)0.4 to 2.00.5 to 6.00.75 to 121 to 16(0.4)(0.8)0.10.10.10.15Adjustable Range Explosion-Proof Model Number12L - N66 - N4 - B1A12L - K614 - N4 - B1A12L - K2 - N4 - B1A12L - K4 - N4 - B1A12L - K5 - N4 - B1A12L - K45 - N4 - B1AProof 400 (psi)Explosion Proof
12NN - K4 - N4 - B1A12NN - K5 - N4 - B1A12NN - K45 - N4 - B1APiston 12Overrange 200 (psi)Weathertight Model Number4NN - K2 - N4 - B1A4NN - K4 - N4 - B1A4NN - K5 - N4 - B1AWeathertight
Typical Dead Band(increasing pressure) psipsi2 to 82 to 253 to 504 to 750.20.30.40.5Adjustable Range Explosion-Proof Model Number4L - K2 - N4 - B1A4L - K4 - N4 - B1A4L - K5 - N4 - B1A4L - K45 - N4 - B1AProof 1000 (psi)Explosion Proof
4NN - K45 - N4 - B1APiston 4Overrange 750 (psi)Standard Construction
• Housing: NN - aluminum; L - cast iron
• Switching Element: SPDT; N - 10 amps @ 250 VAC; K - 15 amps @ 250 VAC
• Diaphragm & O-ring: N4 - primary (wetted) diaphragm, TCP; o-ring (wetted) Buna-N
• Pressure Port: 1/4” NPT(F); B1A - aluminum; F1A - carbon steel
Notes
1. See balance of catalog for construction options.2. Dead band values are expressed as typical expected at mid-range for a particular model number. See Dead Band Considerations on page 8.
3. Design and specifi cations subject to change without notice. For latest revision, see www.sorinc.com.
Form 2164/32Registered Quality System to ISO 9001:2000www.sorinc.com 913-888-2630Pressure and Vacuum SwitchesQuick Selection Guide - Pressure
Weathertight Model Number6NN - K2 - N4 - F1A6NN - K3- N4 - F1A6NN - K5- N4 - F1AWeathertight
Typical Adjustable Range Dead (increasing pressure) Bandpsipsi7 to 3012 to 10020 to 18025 to 27525 to 24035 to 37545 to 550100 to 500200 to 1000200 to 1750500 to 40000.50.91.41.92.23.13.95.39.21598Explosion-Proof Model Number6L - K2 - N4 - F1A6L - K3 - N4 - F1A6L - K5 - N4 - F1A6L - K45 - N4 - F1A5L - K3 - N4 - F1A5L - K5 - N4 - F1A5L - K45 - N4 - F1A9L - K4 - N4 - F1A9L - K5 - N4 - F1A9L - K45 - N4 - F1A1L - K45 - N4 - F1AProof 2500 (psi) 6000 6000Explosion Proof
6NN - K45- N4 - F1A5NN - K3- N4 - F1A5NN - K5- N4 - F1A5NN - K45- N4 - F1A9NN - K4- N4 - F1A9NN - K5- N4 - F1A9NN - K45- N4 - F1A1NN - K45- N4 - F1APiston 6, 5 9 1Overrange 1500 (psi) 2500 5000Standard Construction
• Housing: NN - aluminum; L - cast iron
• Switching Element: SPDT; K - 15 amps @ 250 VAC
• Diaphragm & O-ring: N4 - primary (wetted) diaphragm, TCP; o-ring (wetted) Buna-N
• Pressure Port: 1/4” NPT(F); B1A - aluminum; F1A - carbon steel
Quick Selection Guide - Vacuum
Notes
1. See balance of catalog for construction options.2. Dead band values are expressed as typical expected at mid-range for a particular model number. See Dead Band Considerations on page 8.
3. Design and specifi cations subject to change without notice. For latest revision, see www.sorinc.com.
Weathertight Model Number52NN - K116 - M4 - B1AWeathertight
Typical Adjustable Range Dead Vacuum-O-Pressure Bandin. Hg (in. wc)in. Hg(in. wc)(20 - 0 - 20)(40 - 0 - 40)15 - 0 - 1530 - 030 - 0 - 2030 - 0 - 160(0.9)(1.1)0.50.51.01.4Explosion-Proof Model Number52L - K116 - N4 - B1A52L - K117 - N4 - B1A54L - K117 - N4 - B1A54L - K118 - N4 - B1A56L - K216 - M2 - F1A56L - K316 - M2 - F1AProof 400 (psi)1000 2500Explosion Proof
52NN - K117 - M4 - B1A54NN - K117 - M4 - B1A54NN - K118 - M4 - B1A56NN - K216 - M2 - F1A56NN - K316 - M2 - F1APiston 52 54 56Overrange 200 (psi) 750 1500Standard Construction
• Housing: NN - aluminum; L - cast iron
• Switching Element: SPDT; K - 15 amps @ 250 VAC• Diaphragm & O-ring: N4 - primary (wetted) diaphragm, TCP; o-ring (wetted) Buna-N. Piston 56 primary (wetted) diaphragm, 316SS.
• Pressure Port: 1/4” NPT(F); B1A - aluminum; F1A - carbon steel
www.sorinc.com913-888-2630Notes
1. See balance of catalog for construction options.2. Dead band values are expressed as typical expected at mid-range for a particular model number. See Dead Band Considerations on page 8.
3. Design and specifi cations subject to change without notice. For latest revision, see www.sorinc.com.Form 2165/32Registered Quality System to ISO 9001:2000Pressure and Vacuum Switches
Glossary of Terms
SOR recognizes that there is no industry convention with respect to terminology and defi nitions pertinent to pressure switches. This glossary applies to SOR pressure switches.Pressure Switch
A bi-stable electromechanical device that actuates/deactuates one or more electrical switching element(s) at a predetermined discrete pressure/vacuum (Set Point) upon rising or falling pressure/vacuum.
Adjustable Range
The span of pressure between upper and lower limits within which the pressure switch can be adjusted to actuate/deactuate. It is expressed for increasing pressure.
Set Point
That discrete pressure at which the pressure switch is adjusted to actuate/deactuate on rising or falling pressure. It must fall within the adjustable range and be called out as increasing or decreasing pressure.
Dead Band
The difference in pressure between the
increasing Set Point and the decreasing Set Point. It is expressed as typical, which is an average with the increasing Set Point at mid-range for a pressure switch with the standard K switching element. It is normally fi xed (non-adjustable).
Fire-Safe
The ability of a welded seal pressure sensor to contain the process at elevated temperatures up to 1200°F at the rated overrange pressure, unsupported by the body of the pressure switch.Hermetically Sealed
A welded steel capsule with glass-to-metal, factory-sealed electrical leads that isolates the electrical switching element(s) from the environment.
Overrange
The maximum input pressure that can be continuously applied to the pressure switch without causing permanent change of Set Point, leakage or material failure.
Form 216www.sorinc.com 913-888-2630Proof Pressure
The maximum input pressure that can be continuously applied to the pressure switch without causing leakage or catastrophic material failure. Permanent change of Set Points may occur, or the device may be rendered inoperative.
Repeatability
The ability of a pressure switch to successively operate at a Set Point that is approached from a starting point in the same direction and returns to the starting point over three consecutive cycles to establish a pressure profi le.
Repeatability on SOR switches will be smaller than 1% of full scale per ISA/ANSI S51.1. SPDT Switching Element
Single-Pole, Double Throw (SPDT) has three connections: C — Common, NO — Normally Open and NC — Normally Closed, which
allows the switching element to be electrically connected to the circuit in either NO or NC state.
DPDT Switching Element
DPDT is two synchronized SPDT switching elements which actuate together at increasing Set Point and deactuate together at decreasing Set Point. Discrete SPDT switching elements allow two independent circuits to be switched; i.e., one AC and one DC.
The synchronization linkage is factory set, and is not fi eld adjustable. Synchronization is verifi ed by connecting test lamps to the switching elements and observing them go “On” simultaneously at actuation and “Off” simultaneously at deactuation.
6/32Registered Quality System to ISO 9001:2000Pressure and Vacuum Switches
Step 1: Piston/Spring
6NN-K5-M4-C2A-YYThis table is a listing of piston-spring combinations and the corresponding adjustable ranges, dead bands, overrange and proof pressures. Adjustable range is expressed for increasing pressure; the Set Point must be within the adjustable range. Dead band is expressed as typical. See Dead Band Considerations on page 8.
Piston-Spring Designators12 - 66212 - 614312 - 212 - 412 - 512 - 454 - 24 - 44 - 54 - 456 - 26 - 36 - 56 - 455 - 35 - 55 - 459 - 469 - 569 - 4561 - 456Adjustable Range4psi(in. wc) (0.6 to 2.5)(2.5 to 45)0.4 to 2.00.5 to 6.00.75 to 121 to 162 to 82 to 253 to 504 to 757 to 3012 to 10020 to 18025 to 27525 to 24035 to 37545 to 550100 to 500200 to 1000200 to 1750500 to 4000bar[mbar][1.5 to 6.2][6.2 to 110][30 to 140][35 to 415][50 to 830][70 to 1100][140 to 550]0.14 to 1.70.2 to 3.50.3 to 50.5 to 20.8 to 71.4 to 121.7 to 191.7 to 162.4 to 263.1 to 387 to 3514 to 7014 to 12035 to 275Typical Dead Band1psi(in. wc)(0.4)(0.8)0.10.10.10.150.20.30.40.50.50.91.41.92.23.13.95.39.21598bar[mbar][1][2][7][7][7][10][15][20][30][35][35][60][95]0.10.150.20.250.50.617500034060004102500170600041015001002500170750501000702001440028OverrangepsibarpsiProofbar 1. 2. 3. 4. Dead band values are expressed as typical expected at mid-range with the standard K switching element assembly installed. When optional switching elements are specifi ed, corresponding dead band multipliers shown on pages 8 and 10 must be applied. The 12/66 piston/spring combination is available with the N switching element only.Adjustable range becomes 10 to 45 in. wc whenever switching elements other than K, KA, W or D are used.
Special ranges may be possible. Consult the factory or the SOR representative in your area.
5. Diaphragms may have an additional effect on dead band. See page 13, Note 9.
6. Diaphragm life may be limited by using T or H switching elements with Numbers 1 and 9 pistons.
7. Metric bar (mbar) values are practical equivalents of the reference English values; not necessarily exact mathematical conversions. This data appears on the product nameplate when metric engineering units are specifi ed. 8. A breather drain (Accessory KK, see page 16) should be specifi ed when low pressure adjustable ranges are used in environments with signifi cant ambient temperature changes. 9. Filled isolators attached to the pressure switch will affect dead band.
www.sorinc.com913-888-2630Registered Quality System to ISO 9001:2000Form 2167/32Pressure and Vacuum Switches
Step 1: Piston/Spring
52NN-K116-M4-C2A-YY
This table is a listing of piston–spring combinations and the corresponding adjustable ranges, dead bands, overrange and proof pressures. SOR vacuum switches are compound; they will operate in either vacuum or pressure modes. Adjustable range is expressed from maximum vacuum decreasing to zero gauge and
increasing to maximum pressure. Dead band is expressed as typical. See dead band considerations below. The Set Point must be within the adjustable range. A vacuum switch is generally better suited than a pressure switch for Set Points very near zero gauge.
Adjustable Range2(Vacuum - 0 - Pressure)in. Hg (in. wc)(20 - 0 - 20)(40 - 0 - 40)15 - 0 - 1530 - 030 - 0 - 2030 - 0 - 160bar[mbar][50 - 0 - 50][100 - 0 - 100]0.5 - 0 - 0.51.0 - 01.0 - 0 - 0.71.0 - 0 - 5.4Typical Dead Band1(Vacuum Mode)in. Hg(in. wc)(0.9)(1.1)0.50.51.01.4mbar2317173447Overrange Proofpsi2007501500bar1450100psi40010002500bar2870170Piston-Spring52 - 11652 - 11754 - 11754 - 11856 - 21656 - 316Notes
1. Dead band values are expressed as typical expected at mid-range with the standard K switching element assembly installed. When optional switching elements are specifi ed, corresponding dead band multipliers shown below must be applied.
2. Special ranges may be possible. Consult the factory or the SOR representative in your area.
3. Diaphragms may have an additional effect on dead band. See page 13, Note 9.4. Metric bar (mbar) values are practical equivalents of the reference English values; not necessarily exact mathematical conversions. This data appears on the product nameplate when metric engineering units are specifi ed.
Dead Band Considerations
1. Dead band values are expressed as typical expected at
mid-adjustable range using the standard K switching element. When optional switching elements are specifi ed, corresponding dead band multipliers must be applied.2. Dead bands are fi xed (non-adjustable), except when T or H switching elements are used.
3. Dead band can be adjustable by selecting T or H switching element. (Diaphragm life may be limited when used with Numbers 1 and 9 pistons.)
4. Dead band multipliers must be applied to the typical dead band value shown for piston-spring combination in specifi cations, pages 7 and 8, whenever optional switching elements other than K, KA or W are used.
5. Dead band can be widened by selecting an optional switching element with a multiplier greater than 1.0. Example: Model 6NN-G5-M4-C2A-YY Typical Dead Band 1.4 psi G-Switching Element multiplier = 3 Corrected Typical Dead Band 1.4 x 3 = 4.2 psi6. See item #9, page 7.
Form 216Switching Element DesignatorsK, KA, N, WD, E, J, M, YBDA, B, EF, G, JFL, YYAF, CA, EEC, JJ, SEG, JGAA, BB, GG, KKLLAGTHDead Band Multiplier1.01.52.53.03.54.05.05.56.06.58.52.5 to 6.51.0 to 3.08/32Registered Quality System to ISO 9001:2000www.sorinc.com 913-888-2630Pressure and Vacuum Switches
General Purpose NEMA 1Electrical: 3/4” NPT(F) - RightMaterial: AluminumSee Agency Listings pages 17 & 18.See Switching Element Groups 1, 2, 3 & 4 below.Electrical: 3/4” NPT(F) - Left, RightMaterial: AluminumSee Switching Element Groups 1, 2, 3, & 4 below.Step 2: Housing
6NN-K5-M4-C2A-YYElectrical: Exposed contactsMaterial: AluminumOpen bracket with exposed switching element-does not meet NEMA 1.See Switching Element Groups 1 & 3 below.PPP3H3 Weathertight NEMA 4, 4X, IP65Electrical: 3/4” NPT(F) - RightMaterial: AluminumSee Agency Listings pages 17 & 18.See Switching Element Groups 1, 2, 3 & 4 below.Electrical: 3/4” NPT(F) - Left, RightMaterial: AluminumSee Agency Listings pages 17 & 18.See Switching Element Groups 1, 2, 3 & 4 below.Electrical - RN: 3/4” NPT(F) - RightElectrical - RM: M20 x 1.5 - RightSix-place compression type terminal block Material: AluminumSee Agency Listings pages 17 & 18.See Switching Element Groups 1, 2, 3 & 5 below.Electrical: 3/4” NPT(F) - RightMaterial: AluminumCover: Heavy Duty with Viton gasketSee Agency Listings pages 17 & 18.See Switching Element Groups 1, 2, 3 & 4 below.Electrical - RT: 3/4” NPT(F) - RightElectrical - RS: M20 x 1.5 - RightSix-place compression type terminal blockMaterial: 316SSSee Agency Listings pages 17 & 18.See Switching Element Groups 1, 2, 3 & 5 below.Electrical: 3/4” NPT(F) - RightManual reset onlySix-place compression typeterminal blockMaterial: AluminumSee Agency Listings pages 17 & 18.See Switching Element Group 6 below.NNN3N4N6Electrical: 3/4” NPT(F) - RightMaterial: Carbon SteelSee Switching Element Groups 1 & 3 below.RNRMRT RSRB Conventional Explosion ProofUL Listed Class I, Group C & D; Class II, Group E, F, & G; Divisions 1 & 2 as an outlet box only Electrical: 3/4” NPT(F) - RightMaterial: Cast IronWeathertight with Option CGSee Switching Element Groups 1, 3 below.Ul Listed Class I, Group C & D; Class II, Group E, F, & G; Divisions 1 & 2 as an outlet box onlyElectrical: 3/4” NPT(F) - Left, Right, TopMaterial: Cast IronWeathertight with Option CGSee Switching Element Groups 1, 3, 6 below.Class I, Group A, B, C, & D; Class II, Groups E, F, & G; Divisions 1 & 2 as an outlet box only Electrical: 3/4” NPT(F) - Left, Right, TopMaterial (Housing): AluminumMaterial (Cover): AluminumLine Mounted. Weathertight with Option CG. See Switching Element Groups 1 & 3 below.UL Listed Class I, Groups C & D; Class II, Groups E, F & G; Divisions 1 & 2 as an outlet box onlyElectrical: 3/4” NPT(F) - RightSix-place compression type terminal block with Option LLMaterial: Copper-free aluminumWeathertightSee Switching Element Groups 1, 2 & 3 below.UL Listed Class I, Groups C & D; Class II, Groups E, F & G; Divisions 1 & 2 as an outlet box onlyElectrical: 3/4” NPT(F)-Right, Left, Top Six-place, compression-type terminal block with Option LLMaterial: Copper-free aluminumWeathertightSee Switching Element Groups 1, 2, 3 & 6 below.Separate electrical and set point adjustment compartments. Six-place, compression-type terminal block. Explosion Proof IIB - T4.Material: AluminumRight hand electrical outlet: PF 3/4” (F)See Switching Element Groups 1, 2, & 3 below.Separate electrical and set point adjustment compartments. WeathertightSix-place, compression-type terminal blockUL Listed with WV option, see pages 17 & 18.ATEX with CL option, see page 18. CSA Certifi ed with CS option, see pages 17 & 18.*L*LC*B3*B4*B5*B6Electrical: 3/4” NPT(F) - Left, RightMaterial: AluminumElectrical: M20 x 1.5 - Left, RightMaterial: AluminumElectrical: M20 x 1.5 - Left, RightMaterial: Cast IronElectrical: 3/4” NPT(F) - Left, RightMaterial: Cast Iron*S*SCSwitching Element Groups 1, 2, 3 & 5 below.*TA*J4*Not recommended for direct mount where vibration is expected. Housing should be securely mounted to a fl at surface (bulkhead or panel rack) or pipe stanchion.**Consult the factory.Group 1Switching Element Group/Housing CompatibilityA, AA, B, BB, BD*, C*, CA*, E, EE, G, J, JJ, K, KA, L, N, S, W, YGroup 2GG, KK, LL, YYGroup 3Group 4Group 5AF, AG, EF, EG, JF, JGGroup 6THD, M*BD only available with RN, RT housings.
*C micro switch is not available in L, S and TA housings.
*CA micro switch only available in PP, NN, N3 and N4 housings.www.sorinc.com913-888-2630Registered Quality System to ISO 9001:2000Form 2169/32Pressure and Vacuum Switches
Switching Element ServiceNormal Service ACElectrical Electrical AC RatingContact Connection TypeTypeVoltsAmps2501511151115515Step 3: Switching Element
6NN-K5-M4-C2A-YY
DC Rating ResistiveVolts125--125125125125125Amps0.4*--0.50.5*0.50.5*0.51.5 12525025025025025025010555101515125125125125-125-Minimum Dead Band MultiplierSPDT1.01.01.53.03.03.51.55.0DPDT6.0-5.06.06.06.54.0-DesignatorSPDTKKAJGALECDPDTKK-JJGGAALLEE-Volts302830-303030-Amps5.0*1.0*1.0-5.010*5.0*-Single Switching Element SPDT - (1) SPDTDouble Switching Element DPDT - (2) SPDT Synchronized actuation/deactuation at increasing/decreasing set points.Wide Dead Band ACAC or DCWide Dead Band DCNarrow Dead Band DCVery Wide Dead Band DCVery High-Capacity DCMagnetic Blow-OutHi-Ambient Temperature Rating - 400°FLow Pressure Service 12-66 onlyWide Adjustable Dead BandNarrow Adjustable Dead BandManual Reset - Decreasing Pressure (Automatic Actuation Increasing Pressure)Manual Reset - Increasing Pressure (Automatic Actuation Decreasing Pressure)Hermetically Sealed Switching ElementHermetically Sealed Gold ContactsFM-Approved Service OnlyExplosion Proof EEx d IIC T6K, KA, G, L, C, N, S, Y, W Switching Elements - Screw Terminals.All other Switching Elements _ 18” 18 AWG Color-Coded Wire Leads except when terminal blocks are specifi ed. T & H Switching Elements - Consult Factory.Low PowerGold Contacts12512525025025025025010.0Maximum--------------5.03.01.51.01.02.5 to 6.51.0 to 3.0-6.03.5----SBYWNTH-BBYY----0.30.5*0.3*-0.4*-D250151250.5--1.5-M250250125250250115.01.0227.0125125-1252500.5*0.5*-0.50.25303030-305.05.0*1.0-7.04.03.03.04.02.58.55.55.5--AFEFJFCABD--AGEGJG--Cross reference compatibility chart on page 9 to ensure that switching element will fi t in housing.Review notes on page 11 for more details.
Form 21610/32Registered Quality System to ISO 9001:2000www.sorinc.com 913-888-2630Pressure and Vacuum Switches
Notes
1. Double switching elements have wire leads except when supplied in housings RB, RM, RN, RS, RT, B3, B4, B5, B6 and J4. Terminal blocks are standard in these housings.
2. Dead band multipliers must be applied to the typical dead band fi gures given in the specifi cation tables on pages 7 and 8.
3. Switching element ambient temperature limits:
Step 3: Switching Element
6NN-K5-M4-C2A-YY
6. Certain switching elements can handle greater voltage and/or amperage. Consult the factory should your requirements exceed catalog values. All switching elements above except BD are UL Recognized and CSA Certifi ed. The DC current ratings marked with an asterisk (*) are not UL Listed but have been verifi ed by testing and/or experience.
7. Ambient temperature is reduced to 200°F (93°C) for J, JJ, A, AA, E, EE, B, BB, Y, YY, & W switching elements when CV accessory is selected.
-65 to 400oF (-54 to 200oC) B, Y, W
oo
-65 to 250F (-54 to 120C) A, E, & J
oo
-40 to 167F (-40 to 75C) AF, AG, EF, EG, CAUTION: The switching element assembly
JF, JG
has been precisely positioned in the housing -13 to 158oF (-25 to 70oC) BD
at the factory for optimum performance. Any -65 to 180oF (-54 to 80oC) All others
inadvertent movement or replacement in the fi eld will degrade performance, could render 4. The hermetically sealed switching element
capsule is ATEX Approved, UL Listed, CSA the device inoperative, and can void the Certifi ed and SAA Approved as an explosion-proof warranty unless factory authorized procedures snap switch according to the following table with are followed.
conditions and exceptions specifi ed in Note 3.5. Switching elements W, & Y have Elgiloy springs.
AgencyUL Listed CSA Certifi edHazardous Location ConditionsClass I, Groups A, B, C, & DClass I, Groups E, F & G; Divisions 1 & 2Ex s IIC T6 IP65 Class I, Zone I DIP T6 IP65II 2 G EEx m IIDesignatorAF, EF, AG, EG, JF, JGAF, EF, AG, EGAF, EF, AG, EG, JF, JGSAA ApprovedATEX Approvedwww.sorinc.com913-888-2630Registered Quality System to ISO 9001:2000Form 21611/32Pressure and Vacuum Switches
Notes
1. N4 diaphragm system is standard, but requires
a designator in the model number. It is normally suitable for air, oil, water and noncorrosive processes. M2 diaphragm system is standard on Number 56 vacuum switches. (See notes
10 & 13.)
2. U7 designates a welded fl ush-type diaphragm.
Available only in 1” NPT(M) 316SS on Numbers 5 & 6 pistons with K switching element. See page 15.3. U8 designates the welded fi re-safe diaphragm
system. 316SS is stocked. Not available on Number 1 piston or vacuum switches. Example: U8-C2A is a 316SS fi re-safe welded diaphragm system. See page 15.
4. U9 designates a welded diaphragm system. Not available on vacuum switches.
Example: U9-A1A is a Monel welded diaphragm system. See page 15.
5. Other diaphragm and o-ring combinations may
be available. Consult the factory or the SOR representative in your area for more information.6. Wetted parts have been selected as
representing the most suitable commercially available material for use in the service intended. However, they do not constitute a guarantee against corrosion or permeation, since processes vary from plant to plant and concentration of harmful fl uids, gases or solids vary from time to
time in a given process. Empirical experience by users should be the fi nal guide. Alternate
materials are generally available.
Step 4: Diaphragm & O-Ring
6NN-K5-M4-C2A-YY
O-Ring(Wetted)VitonKalrez*VitonKalrez*VitonKalrez*VitonKalrez*Viton GLTBuna-NVitonNeopreneKalrez*Afl asEPRVitonBuna-NBuna-NKalrez*Kalrez*EPRAfl asBuna-NNeopreneVitonKalrezTCP Tefl on-Coated PolymideBuna-NNeopreneViton316L SSDiaphragm(Wetted Primary)MonelHastelloy-BHastelloy-CCarpenter-20DesignatorA4A6H4H6J4J6L4L6M1M2M4M5M7M8M9 (See Note 11)N1(See Note 13)N3 TCP Tefl on-Coated Polymide(See Note 7)N4 Standard (See Notes 1 & 13)N5(See Note 13)N6N7(See Note 13)N8(See Note 13)P1(See Note 13)R1S1S2W2W4W5W6(Continued on page 13.)
Viton GLTBuna-NVitonNeopreneKalrez*EPRNoneNoneNoneTantalum (See Note 10)EPR Y1WeldedFire-Safe WeldedWeldedU7(See Note 2)U8(See Note 3)U9(See Note 4)*Kalrez or equivalent Perfl uoroelastomer (FFKM) o-ringsForm 21612/32Registered Quality System to ISO 9001:2000www.sorinc.com 913-888-2630Pressure and Vacuum Switches
7. N3 diaphragm system utilizes a durable
back-up diaphragm for high cycle-rate, high shock applications where Buna-N and TCP are compatible with the process. Consult factory if process temperatures are well below freezing.8. This table shows allowable minimum and maximum temperatures for o-rings. Consult the factory for temperatures down to –65°F on fi re- safe and welded metal diaphragm systems.
O-Ring MaterialVitonViton GLTKalrez*Afl asBuna-N Neoprene EPRFire-Safe/Welded Diaphragm SystemTCP Tefl on-Coated Polyimide Diaphragm°F32 to 400-20 to 4005 to 40025 to 400-30 to 200-30 to 400-30 to 400°C0 to 204-29 to 204-15 to 204-4 to 204-34 to 93-34 to 204-34 to 204Step 4: Diaphragm & O-Ring
6NN-K5-M4-C2A-YY
9. Dead bands are slightly higher when using H, J, N3, N6, U or W series diaphragm options. Consult the factory.
10. Diaphragm systems N1, N3, N4, N5, N6, N7, N8, P1, R1, S1, S2, W2, W4, W5, W6, Y1, U8, U9 are not available on Number 56 vacuum switches.
11. M9 diaphragm system is suggested for steam applications up to 400°F.
12. If Kalrez, EPR or Viton is selected for high temperature process media or ambient
temperature requirements, the A, B, E, J, W or Y switching elements are suggested with reference to the table in Note 3, page 11.13. Only diaphragm systems N1, N4, N5, N7, N8 and P1 are available on the 12-66 piston- spring combination.
*Kalrez or equivalent Perfl uoroelastomer (FFKM) o-ringswww.sorinc.com913-888-2630Registered Quality System to ISO 9001:2000Form 21613/32Pressure and Vacuum Switches
PistonProcess Connection SizeAluminum Series 2000 Wrought 356 or 360 CastingCarbon Steel Ledloy Wrought WCB CastingStep 5: Pressure Port
6NN-K5-M4-C2A-YY
12, 452, 546, 5, 91, 5612, 452, 546, 5, 91, 566, 5, 91, 563/4” NPT(M)4, 5412, 5212, 522” NPT(F)1/4” NPT(F)Flushing Port1/4” NPT(F)1/2” NPT(F)1” NPT(M)1” NPT(F)B1A(Standard)-B2A------F1A(Standard)-F2AC2AF3A---Pressure Port Material316 Stainless Steel Wrought CF-8M Casting347 Stainless Steel Wrought CF-8C CastingCarpenter 20 Stainless Steel Wrought CF-7M CastingBrass (See Note 6) Half Hard Yellow Wrought Silicon Brass CastingHastelloy-BHastelloy-CMonelC1AC3AC4A*C5AC6AE1AE2AE3AL1AL2AL3AConsult factory availability of pressure port material and process connection size.D1AH1AJ1AA1AD2AH2AJ2AA2AD3AH3AJ3AA3A*C4A only available with Pistons 5 & 6 when U7 diaphragm is specifi ed. See page 15.
Notes
1. Select designators for material and connection size. Large bold-face letters denote those items generally available from stock. Small light-face letters denote items with limited stock and possible long delivery.
2. 1/4” and 1/2” tapered BSP(F) pressure ports are available. Consult factory.
3. Combinations are possible when a particular connection size is not available for the range (piston/spring) desired. For example, if 2” NPT(F) is desired for a Number 4 piston, the Number 12 pressure port can be supplied. The piston would be designated as Number 124 and the overrange and proof pressures for Number 12 apply. Note: 124, 125 and 126 are the only available combinations.
4. Many other materials such as PVC, Kynar, etc., are available. Denote materials not shown by specifying an X followed by the required connection size, and describe the material.
Form 216
Examples:
X2A = PVC pressure port with 1/2” NPT(F) connection.
X1A = Titanium pressure port with 1/4” NPT(F) connection.
Non-metal pressure ports generally reduce proof pressure and may reduce overrange pressure. The pressure port material may limit the process temperature. Delivery may be longer than normal.5. Raised-face and fl at-face fl anges to match ASA 150 and ASA 300 lb. in commercially available materials can be supplied on Series 12 and 4 pistons by adding an X suffi x to the model numbers and specifying “X - (size) inch (material) (raised- or fl at-) face fl ange to match ASA (rating) lb.”
6. Brass not available on Piston Numbers 9 and 1.7. 1/4” NPT(F) Flushing Port standard on C6A pressure ports.
See next page for presentation of welded diaphragm and FM Approved fi re-safe systems.
14/32Registered Quality System to ISO 9001:2000www.sorinc.com 913-888-2630Pressure and Vacuum Switches
DesignatorDescriptionWelded Diaphragm & Fire-Safe Systems
U7ProcessConnectionProcessFaceWelded Flush-Type Diaphragm SystemA metal diaphragm is welded to the process face of the pressure port, thereby, eliminating the o-ring. This arrangement may be indicated for viscous or slurry process where cleanliness is required or where process build-up and clogging is unacceptable.The pressure port designator determines the material: Only 1” NPT(M) 316SS is available.Example: U7-C4A U7 = 316SS welded fl ush-type diaphragm C4A = 1” NPT(M) 316SS pressure portNote: U7 is limited to Numbers 5 and 6 pistons and the K switching element. Not available on vacuum switches.Fire-Safe Welded Diaphragm SystemFactory Mutual System Approved - U.S Patent Number 4,438,305Tested in fl ames at 1900oF for periods up to 30 minutes while pressurized to the rated overrange pressure.A metal diaphragm, the cylinder disc and the pressure port are welded as a unit, thereby, eliminating the o-ring. This arrangement may be indicated for extremely corrosive, hot, harsh or volatile process where o-rings are not suitable. See fi re-safe defi nition on page 6.316SS is stocked. Hastelloy B and C, Monel and Titanium are available, but may require a longer lead time. The pressure port designator determines the material.Example: U8-C2A U8 = Fire-safe welded diaphragm system C2A = 1/2” NPT(F) 316SS pressure portNote: 1/2” NPT(F) is stocked; 1/4” NPT(F) is not stocked and has a longer lead time. Not available on Number 1 piston and vacuum switches.Welded Diaphragm SystemA metal diaphragm is welded to the pressure port, thereby, eliminating the o-ring. This arrangement may be indicated for extremely corrosive, hot or harsh process where o-rings are not suitable.316SS is stocked. Hastelloy B and C, Monel and Titanium are available, but may require a longer lead time. The pressure port designator determines the material.Example: U9 - A2A U9 = Monel welded diaphragm A2A = 1/2” NPT(F) Monel pressure portNote: Not available on vacuum switches.U8Piston ShaftSpringStopCylinderDiscDiaphragmPressure PortU9DiaphragmPressure PortC6ATwo-inch Pressure Port
The wide pressure port minimizes the possibility of clogging when the process media is sludgy or viscous. See page 20 for dimensions. A 2” NPT(F) pressure port with a 1/4” NPT(F) fl ushing port can be supplied with a welded diaphragm, or with a conventional diaphragm and o-ring combination.
www.sorinc.com913-888-2630Registered Quality System to ISO 9001:2000Form 21615/32Pressure and Vacuum Switches
Accessory/Option & Description Wetted parts are cleaned for industrial oxygen service.Step 6: Accessories
6NN-K5-M4-C2A-YY
Designator BBCLCSCGCVGCGGHBHBMEHTATEX Approved differential pressure switch. Available with B3, B4, B5, and B6 housings. See Agency Listings on page 18 for details.CSA Certifi ed pressure vacuum switch. Available with PP, NN, RB, RN, RT, B3 and B6. Housing has earth (ground) lug. See Agency Listings on page 17 & 18 for details.Neoprene cover gasket (o-ring) to make L, S and TA explosion-proof housings weathertight.Canadian Registration Number (CRN) - Process ratings may be affected. Consult the factory for details.Cemented cover gasket on weathertight housings.Sealed electrical lead adapter. Provides protection to housing interior, switching element and dry side of pressure sensing assembly from condensate in the electrical conduit and corrosive atmospheres. (Protrudes approximately 2” from housing.) Universal terminal box. Stainless steel, 1/2” NPT(F). ATEX Approved EEx d IIC T4, T5 & T6.Universal terminal box. Stainless steel, M20 x 1.5(F). ATEX Approved EEx d IIC T4, T5 & T6.Universal terminal box. Stainless steel, 1/2” NPT(F). FM Approved and CSA Certifi ed. Explosion Proof Class I, Groups A, B, C, & D; Class II, Groups E, F & G; Class III; Divisions 1 & 2 (NEMA 4X IP65)Breather DrainCrouse Hinds ECD-15 for Hazardous Locations Class I, Groups C & D, Class II, Groups E, F & G; on S or SC housings only.Sintered metal plug in weathertight housing.Terminal block. 6-place compression type standard in B and R series housings. Optional in LC and SC housings. 6-place screw type standard in J4 housing.Universal terminal box, “HB” with M20 x 1.5. 316SS. Explosion Proof. ATEX Approved.Vacuum protector plate. Retains diaphragm in pressure switch if subjected to vacuum greater than 10 in. Hg. If a pressure switch is subjected to continuous, rapid changes of vacuum, other protection may be available (consult factory). Material matches or exceeds pressure port material. N/A on Pistons 52, 54, or 56.Compliance to NACE Certifi cation MR0175/ISO 15156.Carbon steel body with stainless steel adjusting nut.Pipe (stanchion) mounting kit for (1-1/2 to 2” pipe). Tag, fi ber. Attached with plastic wire to housing. Stamped with customer-specifi ed tagging information.Powder coat epoxy coating. No coating on stainless steel parts or plated screws. (500 hours-salt spray)Tag, stainless steel. Attached with stainless steel wire to housing. Stamped with customer-specifi ed tagging information. (2 lines, 18 characters and spaces per line.)Stainless steel body and adjusting nut for corrosive environments.Stainless steel piston and cylinder disc for corrosion resistance.Explosion-proof weathertight electrical junction box with screw terminals. 3/4” NPT(F) top or right conduit connections as required. UL Listed and CSA Certifi ed Class I, Groups A, B, C & D; Class II, Groups E, F & G; Divisions 1 & 2. (L, LC, S, SC and TA housing.) Includes cover o-ring for weathertight applications.Oversize stainless steel nameplate or separate stainless steel tag. Permanently attached to housing. Stamped with customer-specifi ed tagging information.Fungicidal varnish. Covers exterior and interior except working parts.UL Listed pressure vacuum switch. Available with B3 and B6 housings. See Agency Listings on page 17 & 18 for details.Epoxy coating. Exterior only. Polyamide epoxy with 316SS pigment. (200 hours-salt spray)Chained cover with captive screws to conform to former JIC specifi cation.“X” is used as a suffi x to the model number for special requirements not keyed elsewhere in the model number by an “X”. Each “X” must by completely identifi ed in the text of the order or inquiry. When more than one “X” is required, use “X” followed by the number of such items. For example, “X3” means three separate otherwise unidentifi able requirements.KKLLMEMMNC*PBPKPPPYRRSBSPTBTTVVWVYYZZXNote: See pages 17 & 18 for Agency Approved, Certifi ed or Listed Accessories Options. Representative Information Only: A slash and a three-digit number (/000) appearing after the last Accessory designator letter in the model number denotes special administrative procedures with respect to factory representatives. It is not part of the model number and is used only by the factory or a factory representative.*Consult the factory for materials other than 316/316L.
Form 216www.sorinc.com 913-888-263016/32Registered Quality System to ISO 9001:2000Pressure and Vacuum Switches
UL
Agency Listings
For Hazardous Locations Class I, Groups B, C, & D; Class II, Groups E, F, & G; Divisions 1 & 2PistonSpringHousing Switching ElementA, AA, B, BB, C, E, EE, G, GG, GA, J, JJ, JL, K, KK, KA, L, LL, N, S, T, W, Y, YYMaximum: 15A @ 300 VAC 10A @ 125 VDCDiaphragm & O-RingA1, A4, A6, H4, H6, J4, J6, L4, L6, M1, M2, M3, M4, M5, M6, M7, M8, M9, N1, N2, N3, N4, N5, N6, N7, N8, P1, R1, S1, S2, W2, W3, W4, W5, W6, Y1, U8, U9Pressure Port Material & AccessoriesConnection SizeWV RequiredAllMM, PB, PC, PK, PP, RR, TT, VV, YY, SA, AB, X1, 4, 5, 6, 9, 12, 45, 46, 52, 54, 56, 124, 125, 1262, 3, 4, 5, 45, 66, 116, 117, 118, 216, 316, 614B3, B6, B8CSA
For Hazardous Locations Class I, Groups A, B, C, & D; Class II, Groups E, F, & G; Divisions 1 & 2PistonSpringHousing Switching ElementA, AA, B, BB, C, E, EE, G, GG, GA, J, JJ, JL, K, KK, KA, L, LL, N, S, T, W, Y, YYMaximum: 15A @ 300 VAC 10A @ 125 VDCDiaphragm & O-RingPressure Port Material & AccessoriesConnection Size1, 4, 5, 6, 9, 12, 45, 46, 52, 54, 56, 124, 125, 1262, 3, 4, 5, 45, 66, 116, 117, 118, 216, 316, 614CS RequiredAllAllAll except LL, KK, ZZB3, B6, B8General Purpose and Weathertight (CSA Enclosure Type 4)PistonSpringHousing Switching ElementDiaphragm & O-RingPressure Port Material & AccessoriesConnection SizeCS RequiredPP A, AA, B, BB, C, (General E, EE, G, GG, Purpose)GA, H, J, JJ, JL, K, KK, KA, L, LL, N, NN S, T, W, Y, YY(Type 4)1, 4, 5, 6, 9, 12, 45, 46, 52, 54, 56, 124, 125, 126A, AA, AF, AG, B, BB, C, E, EE, EF, EG, G, GG, GA, H, J, JJ, JL, JF, JG, K, KK, KA, L, LL, N, S, T, W, Y, YYD, DA, M (Manual Reset only)AllRN, RT (Type 4) AllAllAll except GC, LLRB, RH (Type 4)TIISFor Hazardous Locations Rating: Explosion Proof Class IIBT4PistonSpringHousing Switching ElementA, AA, B, BB, C, E, EE, G, GG, GA, H, J, JJ, JL, K, KK, KL, L, LL, N, S, T, W, WW, Y, YYDiaphragm & O-RingPressure Port Material & AccessoriesConnection SizeMaterial: A, B, C, D, E, F, H, J, LBB, MM, NN, PB, PC, PK, PP, RR, SB, TT, W, YY, X1, 4, 5, 6, 9, 12, 52, 54, 562, 3, 4, 5, 45, 66, 116, 117, 118, 216, 316, 614J3, J4, J5, J6, J7, J8AllConnection Size: 1, 2, 3, 4, 5, 6Thread Type: A, B, Jwww.sorinc.com913-888-2630Registered Quality System to ISO 9001:2000Form 21617/32Pressure and Vacuum Switches
FM
Agency Listings
Pressure Supervisory Switches for Fuel Gas/Fuel Oil, and Ventilating or Combustion AirPistonSpringHousing PP(NEMA 1)1, 4, 5, 6, 2, 3, 4, 5, 9, 1245, 614NNN3N4(NEMA 4)CASwitching ElementDiaphragm & O-RingPressure Port Material & AccessoriesConnection SizeMaterial: A, B, C, KK (PP M2, M4, M5, N1, D, E, F, H, J, LHousing only)N3, N4, N5, N6, BB, MM, P1, R1, S1 U9, Connection Size: 1, 2, 3, 4, 5, 6GG, PP, RR, W2, W4, W5, SS, TT, VV, W6, Y1Thread Type: A, BYY, ZZAirfl ow Interlocking Switches for Ventilating or Combustion AirPistonSpring66 (N Switch)2, 4, 5, 45, 614Housing Switching ElementN (12 Piston only)C, EE, G, K, L, S, T, WDiaphragm & O-RingPressure Port Material & AccessoriesConnection SizePP, RR, SS (SS same as TT)4, 12PF (NEMA 1)P1B1A, B2AATEX
BASEEFA
Electrical Equipment for Flammable Atmospheres Rating: EEx d IIC T6 per EN 50-0 14 & 018BAS Certifi cation Number Baseefa02ATEX0252PistonSpringHousing Switching ElementA, AA, AF, AG, B, BB, C, E, EE, EF, EG, G, GG, GA, J, JJ, JF, JG, JL, K, KA, KK, L, LL, N, S, T, W, Y, YYDiaphragm & O-RingPressure Port Material & AccessoriesConnection SizeCL Required1, 4, 5, 6, 2, 3, 4, 9, 12, 45, 5, 45, 46, 52, 66, 116, 54, 56, 117, 118, 124, 125, 216, 126316, 614B3, B4, B5, B6, B7, B8AllAllAll except CS, GG, KK, LL, WV, ZZForm 21618/32Registered Quality System to ISO 9001:2000www.sorinc.com 913-888-2630Pressure and Vacuum Switches
Manual Reset Button
Manual Reset
RB - WeathertightS - Explosion Proof
SOR Pressure Switches in this catalog may be specifi ed with manual reset electrical switching elements D or M. D actuates automatically on increasing pressure. M actuates automatically on decreasing pressure. Depress the button to manually reset. Housings must be RB (weathertight) or S (explosion proof) because of the requirement of a hub for the manual reset assembly. Refer to page 3 for How to Order instructions.
Shipping Weights
HousingH3NN, N3, N4, PF, PP, P3RB, RM, RNN6LC, SCL, STAB3, B4, J4, RT, RSB5, B6Weight (lbs)1.522.53456810(kgs) 0.7511.251.522.5345Actual shipping weights may vary from the charted values because of product material, confi guration and packaging requirements.Note
PK Pipe Kit adds approximately 1.5 lbs. (0.7 kgs). TB Junction box adds approximately 5 lbs (2.25 kgs).
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certifi ed drawings for a particular model number.
Notes 1. Dimensions in this catalog are expressed as millimeters over inches (Linear = mm/in.). 2. Dimensions marked with an asterisk (*) on housing dimension drawings (pages 20 through 31) vary with respect to process connection size. The chart below lists these dimension variances. 3. Electrical Connection Size: 3/4” NPT(F) standard. 1/2” NPT(F), 1/2” NPT(M), M20 x 1.5, PG 13.5, PF 3/4” optional. Consult the factory for compatibility with selected housing or agency listing.
Process Connection Size1/4” NPT(F)1/2” NPT(F)3/4” NPT(M)1” NPT(F)1” NPT(M)2” NPT(F)Length “A” 1/4” NPT(M)Length “A” 1/2” NPT(M)www.sorinc.com913-888-2630Registered Quality System to ISO 9001:2000Piston Number12, 52ShownShown-Add 5.6 0.22-Add 25.4 1.00Add 29.7 1.17Add 38.9 1.524, 54ShownShown--Add 46.0 1.81-Add 29.7 1.17Add 38.9 1.526, 5, 9, 1, 56ShownAdd 13.2 0.52Add 23.1 0.91---Add 29.7 1.17Add 38.9 1.52Form 21619/32Pressure and Vacuum Switches
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certifi ed drawings for a particular model number.
Drawing # 0091354
Wide Pressure Port: C6A
See description on page 15.
Drawing # 0090300Drawing # 0091353
Pipe Mounting Kit: PK
Form 216Junction Box with Terminal
Block: TB
www.sorinc.com 913-888-263020/32Registered Quality System to ISO 9001:2000Pressure and Vacuum Switches
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certifi ed drawings for a particular model number.
Weathertight - NEMA 4, 4X, IP65
Drawing # 0090100Designators: NN, N3, N4, PP, PF, P3Piston Numbers 12, 52Housings PP, P3 and PF are General Purpose. (Cover gasket is not installed.)Drawing # 0090110Designators: NN, N3, N4, PP, PF, P3Piston Numbers 4, 54Housings PP, P3 and PF are General Purpose. (Cover gasket is not installed.)Drawing # 0090120Designators: NN, N3, N4, PP, PF, P3Piston Numbers 5, 6, 1, 9, 56Housing PP, P3 and PF are General Purpose. (Cover gasket is not installed.)
*Refer to Dimensions table on page 19 for changes in length due to process connection size, including A dimension.
www.sorinc.com913-888-2630Registered Quality System to ISO 9001:2000Form 21621/32Pressure and Vacuum Switches
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certifi ed drawings for a particular model number.
Weathertight - NEMA 4, 4X, IP65HousingElectrical Connection3/4” NPT(F) M20 x 1.5HousingRN, RT, RM, RSElectrical Connection3/4” NPT(F) M20 x 1.5Drawing # 0090247RN, RT, RM, RSDrawing # 0090246Designators: RM, RN, RS, RTPiston Numbers 12, 52Designators: RM, RN, RS, RTPiston Numbers 4, 54HousingElectrical Connection3/4” NPT(F) M20 x 1.5Drawing # 0090245Designators: RM, RN, RS, RTPiston Numbers 5, 6, 1, 9, 56
RN, RT, RM, RS*Refer to Dimensions table on page 19 for changes in length due to process connection size, including A dimension.
Form 21622/32Registered Quality System to ISO 9001:2000www.sorinc.com 913-888-2630Pressure and Vacuum Switches
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certifi ed drawings for a particular model number.
Open Bracket
Drawing # 0090007Designators: H3Piston Numbers 12, 52Drawing # 0090017Designators: H3Piston Numbers 4, 54Drawing # 0090027
Designators: H3
Piston Numbers 5, 6, 9, 1, 56
*Refer to Dimensions table on page 19 for changes in length due to process connection size, including A dimension.
www.sorinc.com913-888-2630Registered Quality System to ISO 9001:2000Form 21623/32Pressure and Vacuum Switches
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certifi ed drawings for a particular model number.
Weathertight - NEMA 4, 4X, IP65
Drawing 0090009Designators: N6Piston Numbers 12, 52Drawing 0090010Designators: N6Piston Numbers 4, 54Drawing 0090020
Designators: N6
Piston Numbers 5, 6, 9, 1, 56*Refer to Dimensions table on page 19 for changes in length due to process connection size, including A dimension.
Form 21624/32Registered Quality System to ISO 9001:2000www.sorinc.com 913-888-2630Pressure and Vacuum Switches
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certifi ed drawings for a particular model number.
Conventional Explosion Proof
Drawing # 0090146Designators: LPiston Numbers 12, 52Drawing # 0090145Designators: LPiston Numbers 4, 54Drawing # 0090144Designators: LPiston Numbers 5, 6, 9, 1, 56*Refer to Dimensions table on page 19 for changes in length due to process connection size, including A dimension.
www.sorinc.com913-888-2630Registered Quality System to ISO 9001:2000Form 21625/32Pressure and Vacuum Switches
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certifi ed drawings for a particular model number.
Conventional Explosion Proof
Drawing # 0090149Designators: SPiston Numbers 12, 52Drawing # 0090148Designators: SPiston Numbers 4, 54Drawing # 0090147
Designators: S
Piston Numbers 5, 6, 9, 1, 56
*Refer to Dimensions table on page 19 for changes in length due to process connection size, including A dimension.
Form 21626/32Registered Quality System to ISO 9001:2000www.sorinc.com 913-888-2630Pressure and Vacuum Switches
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certifi ed drawings for a particular model number.
Conventional Explosion Proof
Drawing # 0090184Designators: LC, SCPiston Numbers 12, 52SC shown. LC identical except right-hand electrical connection only.Drawing # 0090186Designators: LC, SCPiston Numbers 4, 54SC shown. LC identical except right-hand electrical connection only.Drawing # 0090103Designators: LC, SCPiston Numbers 5, 6, 9, 1, 56SC shown. LC identical except right-hand electrical connection only.
*Refer to Dimensions table on page 19 for changes in length due to process connection size, including A dimension.
www.sorinc.com913-888-2630Registered Quality System to ISO 9001:2000Form 21627/32Pressure and Vacuum Switches
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certifi ed drawings for a particular model number.
Conventional Explosion Proof
Drawing # 0090155Designators: TAPiston Numbers 12, 52Drawing # 0090154Designators: TAPiston Numbers 4, 54Drawing # 0090153Designators: TAPiston Numbers 5, 6, 9, 1, 56
*Refer to Dimensions table on page 19 for changes in length due to process connection size, including A dimension.
Form 21628/32Registered Quality System to ISO 9001:2000www.sorinc.com 913-888-2630Pressure and Vacuum Switches
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certifi ed drawings for a particular model number.
Explosion Proof
Drawing # 0090297Designators: B3, B4, B5, B6, J4Piston Numbers 12, 52Drawing # 0090284Designators: B3, B4, B5, B6, J4Piston Numbers 4, 54Drawing # 0090882Designators: B3, B4, B5, B6, J4Piston Numbers 5, 6, 9, 1, 56*Refer to Dimensions table on page 19 for changes in length due to process connection size, including A dimension.
www.sorinc.com913-888-2630Registered Quality System to ISO 9001:2000Form 21629/32Pressure and Vacuum Switches
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certifi ed drawings for a particular model number.
Weathertight - NEMA 4, 4X, IP65
Drawing # 0090269Designators: RB Manual ResetPiston Numbers 12, 52Drawing # 0090270Designators: RB Manual ResetPiston Numbers 4, 54Drawing # 0090271
Designators: RB Manual ResetPiston Numbers 5, 6, 1, 9, 56
*Refer to Dimensions table on page 19 for changes in length due to process connection size, including A dimension.
Form 21630/32Registered Quality System to ISO 9001:2000www.sorinc.com 913-888-2630Pressure and Vacuum Switches
Dimensions
Dimensions in this catalog are for reference only. They may be changed without notice. Contact the factory for certifi ed drawings for a particular model number.
Conventional Explosion Proof
Drawing # 0090167Designators: S Manual ResetPiston Numbers 12, 52Drawing # 0090168Designators: S Manual ResetPiston Numbers 4, 54Drawing # 0090169
Designators: S Manual ResetPiston Numbers 5, 6, 1, 9, 56
*Refer to Dimensions table on page 19 for changes in length due to process connection size, including A dimension.
www.sorinc.com913-888-2630Registered Quality System to ISO 9001:2000Form 21631/32SOR offers a full line of commercial-grade process instruments.
®
echOsonix Level Transmitters
PressureTemperatureLevelSwitches
Flow Switches
Level
TemperatureSwitches
Flow
PressureSwitches
Process Instrumentation
We Deliver Quality On Time
SOR Inc.
14685 West 105th StreetLenexa, Kansas 66215Phone 913-888-2630Toll Free 800-676-6794Fax 913-888-0767
www.sorinc.com
www.echOsonix.com
Form 216Registered Quality System to ISO 9001:2000
SOR Europe, Ltd.
Star Road
Partridge Green, SussexRH13 8RA, United KingdomPhone +44-140-371-1331Fax +44-140-371-0177sales@soreur.co.uk
SOR - China
Room 903, No. 10 Building Wan Da Plaza
No. 93 Jian Guo RoadChao Yang DistrictBeijing, China 100022Phone +86 (10) 5820 8767Fax +86 (10) 5820 8770
32/32www.sorinc.comForm 216 (04.08) ©2008 SOR Inc. 913-888-2630Registered Quality System to ISO 9001:2000