搜索
您的当前位置:首页正文

EN1092-1法兰标准

来源:欧得旅游网
EN1092-1法兰标准

EN1092-1 法兰标准Flanges PN 6 EN 1092-1Dimensions of PN 6 Flanges EN 1092-1

NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange.NOTE 2: For d1 dimensions see document \"Flange facing according to EN 1092-1\".Dimensions in mm

* Above DN 600 dimension C1 is to be specified by the purchaser.

** For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter.

NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to andincluding DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser.Flanges PN 10 EN 1092-1

Dimensions of PN 10 Flanges EN 1092-1

NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange.NOTE 2: For d1 dimensions see document \"Flange facing according to EN 1092-1\".Dimensions in mm

* For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter,

NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to andincluding DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser.Flanges PN 16 EN 1092-1

Dimensions of PN 16 Flanges EN 1092-1

NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange.NOTE 2: For d1 dimensions see document \"Flange facing according to EN 1092-1\".Dimensions in mm

* For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter,** 8 holes is preferred however 4 holes may be supplied upon special request by the purchaser.

NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to andincluding DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser.Flanges PN 25 EN 1092-1

Dimensions of PN 25 Flanges EN 1092-1

NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange.NOTE 2: For d1 dimensions see document \"Flange facing according to EN 1092-1\".Dimensions in mm

* For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter.

NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to andincluding DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser.Flanges PN 40 EN 1092-1

Dimensions of PN 40 Flanges EN 1092-1

NOTE 1: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange.NOTE 2: For d1 dimensions see document \"Flange facing according to EN 1092-1\".Dimensions in mm

* For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter,

NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to andincluding DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser.Flanges PN 63 EN 1092-1

Dimensions of PN 63 Flanges EN 1092-1

NOTE: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange.

Dimensions in mm

* For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter.

NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to andincluding DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser.Flanges PN 100 EN1092-1

Dimensions of PN 100 Flanges EN 1092-1

NOTE: Dimensions N1, N2 and N3 are measured at the intersection of the hub draft angle and the back face of the flange.Dimensions in mm

* For flanges type 21 the outside hub diameter approximately corresponds to the outside pipe diameter,

NOTE: The p/t ratings from EN 1092-1 apply only for flange types 05, 11, 12, 13 and 21 having nominal sizes up to andincluding DN 600. The p/t rating of all other flanges shall be agreed between the manufacturer and the purchaser.FLANGES according to EN 1092-1

Flange facing dimensions according to EN 1092-1 standard

Type A flat faceType Braised faceType Ctongue faceType Dgroove face

Type E spigot Type FreccesType GO ring recessType HO ring groove

* For PN 160 flnages form can be only B2, C and D

因篇幅问题不能全部显示,请点此查看更多更全内容

Top